The high-tech lighting SPD of Qiyutech features 100,000 Hours life, T3 protection class, LED indicator, 40 - 70 °C temperature, 30 strike, Imax 10KA, I-surge 5KA, 275VAC continue voltage, IP20 rating, 15kA max discharge current, 5-95% humidity, and TUV, CE, CQC certification. Strict quality checking guaranteed!
  • Applications
  • Technical data & Specification
  • Outline drawings

They are employed in street lighting, digital signage, floodlighting, outdoor and commercial LED lighting. They are used in traffic lighting, tunnel lighting, roadway lighting and parking garage lighting.


Wiring diagram Insulation Class I application

SPD06-10

Wiring diagram Insulation Class II application

SPD06-10

This surge protector device is developed with thermally protected MOVs that are less in weight and bring more safety. It is protected due to its surge suppression segment which is automated and disconnects when the gadget is introduced to unusual conditions.

They have an inbuilt LED indicator that notifies the users about timely replacements. They are approved by IEC 61643-11/EN 61643-11. They are connected parallel in a circuit. They have a remarkable count of maximum discharge current which is about 10kA. They do not dissipate much power. The ambient temperature lies between -40 to 70°C.

Furthermore, they are reliable and offer endurance.

Continue Voltage UC(V)IP RatingProtection ClassLED IndicatorIncluding Impedance Open-circuit Voltage   Uoc(KV)Protecting Voltage Up(L-N/KV)Protecting Voltage Up(L-PE/KV)Protecting Voltage Up(N-PE/KV)I surge (KA)StrikeImax(KA) 1 time Certificate
275IP20T3YesYes101.52253010CQC, TUV, CE

Technical Information: 

SpecificationsParameterValueUnitCondition
 Certifications


TUV, CE, CQC
Classification
Class III
Acc. IEC61643-11
Protection mode
Diff. mode & Comm. mode

Max. continuous operating voltageUc (L-N)277VAC50 … 60 Hz
Max. continuous operating voltageUc (L-GND)277VAC50 … 60 Hz
Max. continuous operating voltageUc (N-GND)277VAC50 … 60 Hz
Temporary overvoltage TOVUT1505VHV system fault: 1200 V+305, at tt = 200 ms, TT (L-PE)
Temporary overvoltage TOVUT402.6VLV system fault: 305 V x 1.32 at tt = 120 m, TT 、TN
Temporary overvoltage TOVUT528VLV system fault: 305 V x √3 at tt = 5 s, TT 、TN
Power grids
TN, TT,
Incl. all TN varieties TN-C, TN-C-S, TN-S
Nominal  discharge currentIn  (L-N)7.5kA@ Uoc=15KV;internal resistance=2Ω
Nominal  discharge currentIn  (L-GND)7.5kA@ Uoc=15KV;internal resistance=2Ω
Nominal  discharge currentIn  (N-GND)7.5kA@ Uoc=15KV;internal resistance=2Ω
Max. voltage protection level at InUp  (L-N)1,5kV@ Uoc=15KV;internal resistance=2Ω
Max. voltage protection level at InUp  (L-GND)2kV@ Uoc=15KV;internal resistance=2Ω
Max. voltage protection level at InUp  (N-GND)2kV@ Uoc=15KV;internal resistance=2Ω
Open-circuit voltageUoc15kV
Backup fuse
8Amax., gG fuse
End of life indication
yes
Optical,  light ON: SPD is functional. Light OFF: SPD has reached end-of-life
Max earth leakage current at Uc
50µAMax. rms, to GND

   Other specifications

SpecificationsParameterValueUnitCondition
Surge withstand capability
1strikemax. at 10 kA

30strikesmin. at 7.5 kA

50strikesmin. at 5 kA
Nominal  current
4ARated load current at 50 … 60 Hz
Power consumption
1.1Wmax. at Uc = 277VAC; Load current=4A
Suitable for luminaires
Class I、Class II
Insulation Class acc. IEC60598

 Protection levels Up

IC  8/20 μsDifferential mode U2Common mode U1/U2
7.5kA≤1500 V≤2000 V / 1500 V

SPD06-10SPD06-10

Environmental conditions

Specification itemValueUnitCondition
Ambient temperature-40…70°C
Tcase-max.80°CMeasured at Tc-point
Storage temperature-40…85°C
Relative humidity5…95%Non-condensing
Suitable for outdoor luminairesYes
Built-in only

   Lifetime

Specification itemValueUnitCondition
Lifetime100,000hoursMeasured @ Tcase-max with min 90% survival




SPD06-10

Specification itemValueUnit
Mounting length70.5mm
Overall length70.5mm
Case Width42.5mm
Case Height33mm
Fixing hole diameterM4(60*32)mm
Max. screw torque0.45Nm
Weight105gr

 Wiring

Specification itemValueUnitCondition
Connector typePush-in
Single wire only
Wire diameter0.5…2.5mm2Solid and stranded